- Rugged overmoulded polycarbonate housing provides unsurpassed durability, including ability to survive 10 ft (3 m) drop; IP65-certified
- Field-proven integral pump provides consistent gas flow, eliminating concerns of externally-attached components
- High performance XCell Sensors last longer- typical life greater than 4 years for combustible, O2, CO/H2S, SO2, CO/NO2 and CO (high concentration) sensors and greater than 3 years for NH3 and Cl2 sensors
- Most sensor response and clear times <15 seconds
- Rapid bump test gives results in less than 10 seconds for most common sensor configurations
- Span calibration time of 60 seconds for most common sensor configurations
- MotionAlert feature option tells others that user has become immobile
- InstantAlert feature provides manual alarm to alert others as to a potentially hazardous situation
- Large buttons and bright display provide easy operation, even when users wear gloves
- Exclusive end-of-sensor warning cautions users when unit's sensor nears end-of-life
- Wireless Bluetooth included standard
- Methane 0-100% LEL (0-4.4% Vol) O2 0 -30% Vol, CO 0-1999 ppm & H2S 0-200 ppm, Carbon Dioxide (CO2) 0-10 %/Vol
EN 60079-0: 2012
EN 60079-1: 2014
EN 60079-7: 2007
EN 60079-11 :2012
EN 60079-18: 2009
EN 50303: 2000
EN 60079-29-1:2007
EN 50104: 2010
EN 50271: 2010
EN50270: 2006 Type 2
EN 61000-6-3: 2011
EN 61010-1: 2010
EN 301 489-1, V1.9.2: 2011-09
EN 301 489-3 V1.6.1: 2013-08
EN 301 489-17 V2.2.1: 2012-09
EN 60945: 2002